[. . . ] capacity washer) or 1½" (38 mm) (to match height of 3. 8 cu. [. . . ] See “Venting Requirements. ”
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
■■ Additional spacing should be considered for ease of installation
and servicing. moldings.
■■ Additional clearances might be required for wall, door, and floor ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
■■ For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■■ Companion appliance spacing should also be considered.
INSTALLATION REQUIREMENTS
GAS SUPPLY REQUIREMENTS
Gas supply: This dryer is equipped for use with Natural gas. Exhaust systems longer than those specified will:
■■ Shorten life of dryer. ■■ Reduce performance, resulting in longer drying times
and increased energy usage.
Louvered Hood
Box Hood
The “Vent System Chart” provides venting requirements that will help achieve best drying performance.
Acceptable Style:
Number of 90° turns or elbows 0 Angled Hood 1 2 3 4
Vent System Chart
Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered hoods 64 ft. (6. 4 m)
Determine vent path:
■■ Select route that will provide straightest and most direct
path outdoors.
■■ Plan installation to use fewest number of elbows and turns. [. . . ] (21. 3 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. [. . . ]